Sign In | Join Free | My himfr.com
Home > Fan Filter Unit >

Cold Plate Paint Low Power Energy Saving AC HEPA Fan Filter Unit H14 Filter

Dongguan Amber Purification Engineering Limited
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Cold Plate Paint Low Power Energy Saving AC HEPA Fan Filter Unit H14 Filter from wholesalers
     
    Buy cheap Cold Plate Paint Low Power Energy Saving AC HEPA Fan Filter Unit H14 Filter from wholesalers
    • Buy cheap Cold Plate Paint Low Power Energy Saving AC HEPA Fan Filter Unit H14 Filter from wholesalers
    • Buy cheap Cold Plate Paint Low Power Energy Saving AC HEPA Fan Filter Unit H14 Filter from wholesalers
    • Buy cheap Cold Plate Paint Low Power Energy Saving AC HEPA Fan Filter Unit H14 Filter from wholesalers
    • Buy cheap Cold Plate Paint Low Power Energy Saving AC HEPA Fan Filter Unit H14 Filter from wholesalers

    Cold Plate Paint Low Power Energy Saving AC HEPA Fan Filter Unit H14 Filter

    Ask Lasest Price
    Brand Name : Amber
    Model Number : AM-FFU024
    Certification : CE, ISO
    Payment Terms : L/C, D/A, D/P, T/T
    Supply Ability : 1000 set per month
    • Product Details
    • Company Profile

    Cold Plate Paint Low Power Energy Saving AC HEPA Fan Filter Unit H14 Filter


    The AC HEPA Fan Filter Unit is a terminal purification device that integrates a fan and a high-efficiency air filter (HEPA) or ultra-high-efficiency air filter (ULPA) within a single module.


    This product utilizes a cold plate spray coating process, resulting in a corrosion-resistant and easy-to-clean surface. Equipped with an H14-grade HEPA filter (filtration efficiency ≥99.997%, MPPS particles), it effectively removes suspended particulates ≥0.3μm, ensuring cleanroom air purification requirements of Class 100 to 10,000.


    The unit features an optimized internal air duct structure and a low-power AC fan, ensuring high filtration efficiency while providing stable and uniform airflow distribution, minimizing turbulence and dead spots. It is commonly used for terminal air supply in cleanrooms such as chip manufacturing, pharmaceutical production, food processing, cosmetics production, and modular operating rooms.


    Why AC FFUs are More Energy-Efficient Than DC FFUs


    Many users often perceive DC fans as more energy-efficient. However, in industrial purification equipment, AC HEPA Fan Filter Units offer significant energy-saving advantages in specific application scenarios:


    Stable Constant Speed Characteristics


    AC fans offer high speed stability, making them suitable for long-term, constant air volume cleanroom operation. They eliminate the need for frequent speed adjustments, thus reducing energy consumption fluctuations.


    Efficiency Range More Suitable for Purification Applications


    Under rated operating conditions, the AC fan's energy efficiency ratio (air volume/power consumption) closely matches the purification system's resistance curve, enabling it to maintain high static pressure output at low power input, reducing excess energy consumption.


    Low Long-Term Operation and Maintenance Costs


    AC fans offer a simple structure and long motor life, eliminating the labor and spare parts costs associated with frequent replacement and commissioning, indirectly reducing overall lifecycle energy consumption and costs.


    Based on our extensive product testing, the Industrial Fan and Filter Unit (IFFU) can reduce total power consumption by 5%-10% compared to some low-end DC solutions at the same cleanroom cleanroom level, making it ideal for continuously operating cleanrooms.


    HEPA Fan Filter Unit Installation Precautions


    During cleanroom construction, the installation accuracy of the HEPA Fan Filter Unit directly impacts air cleanliness and operating costs. Key considerations include:


    Correct Filter Installation Orientation


    HEPA/ULPA filters have an inlet side and an outlet side. Installing them in the wrong direction will result in:


    • Significantly reduced filtration efficiency, preventing the design cleanroom level from being achieved

    • Increased air resistance, hindering air intake, increasing fan load and energy consumption

    • Shortened filter life

    Sealing Strip Integrity Check


    Before installation, ensure that the sealing strip between the filter and the housing is not damaged or warped. Otherwise, bypass leakage will occur, impacting cleanroom performance.


    Air Velocity and Pressure Differential Testing


    After installation, air velocity and static pressure should be tested to ensure even airflow distribution and operation within the system resistance curve.


    Avoiding secondary contamination


    The installation process should be performed in a cleanroom environment. Operators must wear cleanroom clothing to prevent dust, fibers, and other impurities from entering the filter.


    FFU Fan AC Motor vs DC Motor


    TypeDC MotorAC Motor
    Energy ConsumptionLow power consumptionHigh energy consumption
    AdvantagesEnergy-saving, long lifespanAffordable and easy to maintain
    Noise level55dBA±5dBA58dBA±5dBA

    Our DC motors are Japanese Nidec brand. If your budget is high, you can choose a DC FFU.


    If you require a higher level of air filtration, our Amber Team can also provide customized ULPA Fan Filter Unit solutions. We offer one-stop services including design, installation, and commissioning to ensure long-term, stable operation of your cleanroom. Please contact us if you require any assistance.

    Cold Plate Paint Low Power Energy Saving AC HEPA Fan Filter Unit H14 Filter


    Cold Plate Paint Low Power Energy Saving AC HEPA Fan Filter Unit H14 Filter


    Fan Filter Unit Specifications


    ModelFFU-500FFU-1000FFU-1500FFU-2000

    out size mm

    (W*L*H)

    575*575*230575*1175*230875*1175*2301175*1175*230

    Filter size mm

    (W*L*H)

    570*570*69570*1170*69870*1170*691170*1170*59
    Air flow500m³/h1000m³/h1500m³/h2000m³/h
    Pressure210Pa210Pa220Pa230Pa
    Power170W170W210W275W
    Noise47-55dB47-55dB50-58dB50-58dB
    Weight27KG34KG46KG55KG
    CleanlinessClass 100 (ISO 14644-1)
    MaterialStainless steel/ Galvanized steel/ Coated steel
    VoltageAC 220V/50HZ AC 380V/50HZ

    FAQ

    Q1: What environments are suitable for the Industrial Fan and Filter Unit?
    A: This device is widely used in environments requiring high cleanliness, such as chip manufacturing plants, pharmaceutical plants, food processing plants, cosmetics production plants, and modular operating rooms. It supports terminal air distribution in cleanrooms rated from Class 100 to Class 10000.


    Q2: How often should the HEPA or ULPA filter be replaced?
    A: The replacement cycle depends on the operating environment and operating time. It is generally recommended to test the filter differential pressure every 12 to 18 months. If the differential pressure increases significantly or the air volume decreases, the filter should be replaced promptly. If the cleanroom is subject to long-term, high-intensity operation, early inspection and maintenance are recommended.

    Cold Plate Paint Low Power Energy Saving AC HEPA Fan Filter Unit H14 FilterCold Plate Paint Low Power Energy Saving AC HEPA Fan Filter Unit H14 Filter

    Cold Plate Paint Low Power Energy Saving AC HEPA Fan Filter Unit H14 Filter

    Cold Plate Paint Low Power Energy Saving AC HEPA Fan Filter Unit H14 Filter

    Cold Plate Paint Low Power Energy Saving AC HEPA Fan Filter Unit H14 Filter

    Cold Plate Paint Low Power Energy Saving AC HEPA Fan Filter Unit H14 Filter

    Cold Plate Paint Low Power Energy Saving AC HEPA Fan Filter Unit H14 Filter


    Quality Cold Plate Paint Low Power Energy Saving AC HEPA Fan Filter Unit H14 Filter for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Dongguan Amber Purification Engineering Limited
    *Subject:
    *Message:
    Characters Remaining: (0/3000)